Flat black LSZH Ethernet cable with shielded RJ45 connectors and molded strain relief.

LSZH, PTFE, and TPE: Specifying Materials for Custom Cable Assemblies

LSZH, PTFE, and TPE aren’t equivalent material classifications. LSZH describes low-smoke, halogen-free performance characteristics, while PTFE and TPE identify polymer families. Confusing these distinctions can lead to incomplete material specifications for custom cable assemblies.

LSZH: Defining the Required Performance

An LSZH designation alone doesn’t establish compliance with every applicable fire-performance requirement.

Relevant standards may include:

  • IEC 61034:Smoke density.
  • IEC 60754:Halogen acid gas emissions and acidity or conductivity of combustion gases.
  • IEC 60332:Flame propagation.

These evaluate different characteristics. Compliance with one doesn’t establish compliance with the others, and none should be assumed to establish circuit integrity during a fire.

Specifications should identify the applicable test methods, acceptance criteria, and materials covered.

PTFE and TPE: Construction and Compatibility

PTFE-insulated wires and TPE-insulated or jacketed cables can differ substantially in finished dimensions, flexibility, and processing requirements.

Material changes can affect wire stripping, contact compatibility, sealing hardware, molded transitions, and strain relief—even when conductor size remains unchanged.

The specific construction and compound matter more than the general material designation.

A further distinction is important for halogen-free requirements: PTFE contains fluorine, a halogen. A component incorporating PTFE therefore cannot automatically be treated as halogen-free, regardless of the characteristics of other cable materials.

Compliance Across the Completed Assembly

A cable jacket meeting specified LSZH requirements doesn’t establish that every polymer component in the finished assembly meets those requirements.

Conductors’ insulation, protective sleeving, heat-shrink tubing, molded boots, and strain-relief components may use different materials.

Where low-smoke or halogen-free requirements apply to the completed assembly, the specifications must define which components are covered and what evidence of compliance is required.

This is particularly relevant when material substitutions or additional protective components are introduced during manufacturing.

Custom Cable Assemblies at TMC

TMC–The Mate Company manufactures custom cable assemblies and wire harnesses using insulation materials including LSZH, PTFE, and TPE.

Sourcing assemblies with specific insulation, jacket, or material requirements? Request a quote or contact TMC’s sales team with your drawings and specifications.